jiskoot_logo top bar
Home|
Contact Us|
News|
Sampling|
Blending|
Multiphase|
Systems|
Teach Me|
Calculations|
Downloads|
Service & Support|
Sales offices|
Site Map|
Vacancies|
Agents Area|
nav
Quick Search
nav
find>>
quick search
 

Valid HTML 4.0!Valid CSS!
space space space
space > > Multiphase |Systems |Wet gas measurement | space
space
Molecular sieves for measuring liquid content in wet gas
  • Suitable for Murdock/Chisholm/De Leeuw correction
  • Suitable for well test measurement in high GVF
  • High accuracy liquid measurement (mass/volume)
  • High accuracy gas measurement (mass/volume)
  • Liquid sample for composition analysis
  • Gas sample (dry) for analysis
  • Uncertainty better than 0.5% 
top_grey
 
space
A wet gas sampling system can be used as a high accuracy alternative to tracer techniques and multiphase flow meters in high GVF well test and allocation measurement applications.  Samples can also be used to correct the over-measurement caused in DP meters by the presence of liquid in the gas and can be analysed to determine the hydrocarbon/methanol/water ratio of the liquid and the energy value of the gas.
The patented Jiskoot wet gas sampling system comprises a take-off probe and a bypass loop in an enclosure containing a mass flow meter, two molecular sieves and two sample collection receivers. The take-off probe is mounted in the line at a suitable position and has multiple inlet points to profile the pipeline. The number and size of the inlets are designed for each application dependant on the flow regimes present.  The flow loop is designed to maintain sample representivity through the bypass loop and to have minimal dead volume.
top_grey
 
space
The wet gas flows through a molecular sieve, which removes and traps all the liquids from the gas stream. The liquid is retained in the sieve and the mass flow of dry gas is measured by the flow meter. A sample of dry gas is also taken for analysis.  The molecular sieves will have been weighed using a mass balance before placing in the system.  At the end of the sampling process the molecular sieves are removed and weighed and the increase in mass noted. Dual wet-gas sampling system for BP Juno project
top_grey
 
space
The liquid mass ratio to dry gas is established by comparing the mass of liquids collected with dry mass of gas from which it was extracted.  This ratio can be used in a variety of equations to directly compensate the wet gas measurement totals.
top_grey
 
space
Once removed from the system the sample of dry gas can be analysed in the laboratory.  The liquid trapped in the molecular sieve can be removed using a laboratory sample extractor and the liquid samples analysed for content.
top_grey
 
space
The patented Jiskoot wet gas sampling system offers a very high accuracy alternative to tracer techniques and multiphase meters in high GVF measurement applications.
top_grey
 
space
space
space
Some downloads are in PDF format (marked with a red symbol) and you will need Adobe Acrobat installed on your machine in order to open them.

Click here to download a free copy of Adobe Acrobat Reader
Click on the Adobe logo on the right hand side to download a free copy of Adobe Acrobat Reader from the Adobe website.


space
space

Tel: +44 1892 518000
Tel: +1 281 583 0583
Fax: +44 1892 518100
Fax: +1 281 583 0587
Email: information@jiskoot.com Email:sales@usa.jiskoot.com

Web content Management systems by Netsite Ltd
space
space
space
Newsletter
Keep up to date with latest innovations|
Consider these
Mixmeter multiphase meter
Multiphase sampling
news line


www.c-a-m.com|